How far apart should solar panel rows be on a flat roof?

A simple way to space tilted solar rows on a flat roof so they don't shade each other in winter, with real numbers for different latitudes and a worked example.

On a sloped roof you lay the panels flat against the tiles and you're done. On a flat roof you have a choice to make: tilt the panels up toward the sun, and every row throws a shadow on the one behind it.

Put the rows too close and you lose a chunk of your winter mornings and afternoons. Put them too far apart and you've thrown away roof space you paid for. The right gap sits somewhere in between, and it's easier to work out than most people think.

Why rows shade each other

A tilted panel is a small wall. The back edge sits higher than the front, and when the sun is low it casts a shadow straight onto the next row.

In summer the sun is high and the shadow is short. In winter, especially in the morning and late afternoon, the sun drops and the shadow stretches out. If the next row starts inside that shadow, part of it goes dark, and because panels are wired in strings, a shaded strip at the bottom of one row can pull down far more than its share.

Side view of two tilted solar rows on a flat roof. A dashed line from the low winter sun grazes the top of the first row and reaches the roof where the second row begins. The height of the first row is marked h, and the shadow length on the roof is marked as the gap, equal to h times a spacing factor.

The rule installers use

Most designers aim for one thing: no row shades another between 10 am and 2 pm on the shortest day of the year. Those four hours carry most of the winter energy, and if they're clear, the rest of the year takes care of itself.

You only need two numbers:

  1. The height of the row, h. That's how much higher the back edge sits than the front. For a panel of length L tilted at angle θ, it's L × sin θ. A standard panel laid landscape (1.13 m along the slope) at 10° stands about 0.20 m tall at the back. At 15° it's about 0.29 m.
  2. A spacing factor for where you live. It depends on how high the sun gets at 10 am on the shortest day.

Gap between rows = h × spacing factor

Roughly where Factor Gap, 10° tilt Gap, 15° tilt
Mumbai, Hong Kong, Hawaii 1.0 0.20 m 0.30 m
Los Angeles, Sydney, Perth, Cape Town 1.8 0.35 m 0.52 m
New York, Madrid, Melbourne 2.4 0.46 m 0.69 m
London, Berlin, Vancouver 4.7 0.93 m 1.39 m

At 10 am on the shortest day the sun is about 38° high in the first row of places, 26° in the second, 20° in the third and only 11° in the last. Gaps are for a landscape panel 1.13 m along the slope, measured from the back edge of one row to the front edge of the next.

South of the equator the shortest day is in June, not December, and the panels face north, but the numbers work the same way.

If you're somewhere not on the list, pick the row closest to your latitude. The factor climbs quickly once you go past about 45°, which is why flat roofs in northern Europe often use very low tilts.

A worked example

Take a flat roof in Los Angeles with a usable area of 10 m from front to back and 9 m across, after leaving space at the edges. We'll use 430 W panels laid landscape (1.72 m wide, 1.13 m along the slope).

At 10° tilt:

  • Each row takes up 1.11 m of roof front to back, plus a 0.35 m gap. That's 1.46 m per row.
  • 10 m fits 7 rows. Each row holds 5 panels across (5 × 1.72 m = 8.6 m).
  • That's 35 panels, or 15 kW.

At 25° tilt:

  • Each row stands taller (0.48 m), so it needs a 0.86 m gap. With the 1.02 m footprint, that's 1.88 m per row.
  • 10 m fits only 5 rows: 25 panels, or 10.75 kW.

In Los Angeles, 25° gives each panel only around 4–5% more energy over a year than 10°. You'd be trading 10 panels for a few percent. Unless the roof is so big that space doesn't matter, the lower tilt wins easily.

That's the pattern almost everywhere: on a flat roof, a lower tilt with tighter rows usually beats a steep tilt with big gaps. Steeper tilts start to make sense when you're short on budget rather than space, or you need to clear snow.

Don't forget the parapet

The low wall around a flat roof shades the front row just like a panel would. Use the same factor: a 0.6 m parapet in Los Angeles needs the first row to start about 1.1 m back from the wall (0.6 × 1.8).

Same goes for water tanks, AC units and stair rooms. Measure how tall they are, multiply by your factor, and keep that distance clear on the side away from the sun.

Other things that set the gap

Shade isn't the only reason to leave space between rows:

  • Walkways. Someone has to clean and service the panels. Many installers leave a wider aisle every few rows, even if the shade gap is small.
  • Fire codes. Some cities require clear paths across the roof. Check your local rules before you finalise the layout.
  • Wind. Taller, steeper rows catch more wind, which means more ballast or stronger fixings. Low tilts are easier on the roof structure.

What about east–west layouts?

There's another option on flat roofs: tilt pairs of rows back to back, one facing east and one facing west, with almost no gap between them. You lose roughly 10–15% of the energy per panel compared to facing the equator, but you can fit far more panels in the same space, and the low profile handles wind well.

East–west works well on small roofs, and on commercial buildings that use most of their power during the day, because the output is spread more evenly from morning to evening.

Try it on your own roof

Doing this by hand is fine for one rectangle, but real roofs have tanks, odd corners and parapets on three sides. In Solarqivo you draw the roof on the satellite image and choose racked panels on a flat face. The designer spaces the rows for the low winter sun at your exact location and counts the row-to-row shading in the yearly estimate. Auto-design can also try a few tilts and spacings and show you which gives the most energy from the space you have.

If the panel count is your first question, start with how many solar panels fit on my roof. For the tilt itself, see the best tilt and direction for solar panels.